MCB 2P 4.5KA 40A 110V/230V/400V Curve C Type AC Miniature Circuit Breaker
General
1. MCB is for non-professional operation by those untrained, and no maintenance is required.
2. Satisfying conditions and applications as mentioned above,MCB with “ON-OFF” indicating device is considered suitable for isolation function.
3. Particular devices such as surge protective devices,surge arrester etc are recommended to install at upstream line to MCB as precaution against potential surge voltage and current occurring at its power input side.
4. Appropriate tripping curve being chosen and properly installed, MCB trips and switches off its protected circuit in case of fault, and thus provides protection against electric shock.
5. B,C,D tripping curve(see graphics 1):
Feature
1. Protection against both overload and short circuit
2. Contact position indication
3. Applicable to terminal and pin/fork type Busbar connection
4. Easy mounting onto 35mm DIN rail
Type designation
MODEL: CJB 1N-63 (A)1P+N C 63 |
CJ |
Enterprise code |
B |
Miniature Circuit Breaker |
|
1N |
Design Code. |
|
63 |
Frame rating rated current |
|
(A) |
Breaking Capactity A:4.5kA No mark: 6kA |
|
1P+N |
Number of poles(1P/1P+N/2P/3P/3P+N/4P) |
|
C |
Instantaneous trip characteristic type(B/C/D) |
|
63 |
Rated current (A) |
Product Parameters
Model |
TGB1N-63 |
Standard |
IEC60898-1 GB/T10963.1 |
Certification |
CE/CCC |
Poles |
1P/1P+N/2P/3P/3P+N/4P |
Rated Frequency(Hz) |
50/60 Hz |
Frame Degree Rated Current(A) Inm |
63A |
Rated Current(A) Ie |
1A/2A/3A/4A/5A/6A/10A/16A/20A/25A/32A/40A/50A/63A |
Rated Voltage(V) Ue |
AC 230/400V(1P) AC 230(1P+N) AC 400(2P/3P/3P+N/4P) |
Rated Insulation Voltage(V) Ui |
690V |
Rated Impact voltage(kV) Uimp |
4kV |
Rated short circuit breaking capacity(kA) lcn |
6kA |
Tripping Curve |
B(3In~5In) |
C(5In~10In) |
|
D(10In~14In) |
|
Trip Type |
Thermal-magnetic |
Electrical Life(times) |
10000 times |
Mechanical Life(times) |
20000 times |
IP Grade |
IP 20 |
Ambient temperature(℃) |
-35℃~+70℃ |
Installation altitude(m) |
No more than 2000m |
The main technical parameters of the product (see Table 1)
Product name |
CJBIN-63A |
CJBIN-63 |
Standards |
IEC60898-1 |
IEC60898-1 |
Certificate |
CE |
CE |
Electrical characteristics |
||
Number of poles |
1P,1P+N,2P,3P,3P+N,4P(N pole can be opened and closed) |
1P, 1P+N,2P,3P,3P+N,4P (N pole can be opened and closed) |
Rated frequency (Hz) |
50/60 |
50;60 |
Frame rating current (A) Inm |
63 |
63 |
Raied current (A) le |
1,2,3,4,5,6,10,16, 20,25,32,40,50,63 |
1,2, 3, 4, 5,6, 10,16,20,25,32,40,50,63 |
Rated voltage (V) Ue |
AC230/400(1P) AC230(1P+N) AC400(2P, 3P, 3P十N, 4P) |
“AC230/400(1P) AC230 (1P+N) AC400(2P,3P, 3P十N,4P) |
Rated insulation voltage (V) Ui |
690 |
690 |
Rated impulse withstand voltage (kV) I Jimp |
4 |
4 |
Rated short-circuit breaking capacity (kA) lcs |
4.5 |
6 |
Rated short-circuit breaking capacity (kA) lcn |
4.5 |
6 |
Instantaneous trip characteristics |
B(3In〜5In) C(5In~ 10In) D(10In〜14In) |
B(3In〜5In) C(5In-10In) D(10In-14In) |
Trip form |
Thermal magnetic trip |
Thermal magnetic trip |
Pollution level |
2 |
2 |
Eleclrical and mechanical accessories |
MX: Shunt release OF: Auxiliary contact SD: Alann contact MX+OF: Shunt release + auxiliary contact MV: Overvoltage release MN: Undcrvoltage release MV+MN: Overvoltage and undcrvoliagc release MNS: No-voltage release |
|
Mechanical properties |
Products Description
Residual Current Protection
|
Electrical Safety
|
Fire-proof Body
|
Protect circuit from fire caused by circuit false
|
Cold and Heat-resistant -5℃-40℃
|
Reliable and Long-lasting
|
2000 Electrical Cycles
|
4000 Mechanical Cycles
|
Visualized Indication
|
Clear View of On-Off Status
|