En transformador de aislamiento provides galvanic separation between the power source and the load to improve safety and clean up noisy power. At its simplest — often a 1:1 device — the primary and secondary windings are magnetically coupled but electrically isolated, so hazardous direct connection to the utility neutral/earth is removed. This makes isolation transformers ideal where low leakage, reduced common-mode noise, surge attenuation and human safety matter.
How it works (simple, authoritative)
Transformers obey the turns ratio relationships. U1/U2=N1/N2 and I1/I2=N2/N1. In a 1:1 isolation transformer the nominal voltage and current remain the same while the primary and secondary circuits are electrically decoupled.
Because the secondary is floating relative to earth, there is no fixed line-to-earth potential on either secondary conductor — touching one conductor alone will normally not create a return path through earth and therefore reduces touch-shock risk. Carefully designed isolation transformers can also:
Attenuate certain harmonic content (e.g., third-order harmonics in specific winding/vector configurations),
Reduce common-mode interference and noise,
Limit surge energy through magnetic saturation or selected core design, and
Provide a new, stable neutral/reference for sensitive control and measurement systems.
Note: transformers do not change frequency and are not a substitute for active harmonic filters when high-order harmonics are present.
Aplicaciones típicas
Service and maintenance power (safe working voltage for technicians)
Test benches, oscilloscope and audio equipment repair (floating secondary for safety)
Medical and laboratory equipment (use certified medical isolation models)
Industrial control panels, PLCs and CNC machines (noise suppression and clean sampling signals)
AV and high-fidelity audio systems (improved S/N)
Data centers, telecom, UPS input conditioning and lighting where leakage current and EMI must be minimized
Key benefits
Electrical safety: reduces touch-shock risk and isolates equipment from utility faults.
Noise & EMI suppression: reduces common-mode noise and helps prevent equipment-generated harmonics from polluting the grid.
Surge attenuation: core design and winding layout provide some protection from transients.
Customizable: voltage ratios, impedances, shielding and enclosures tailored to your environment.
Enclosure & IP rating — cabinets, IP/weatherproofing, seismic bracing.
Standards & certification — medical, UL/EN/IEC testing or custom reports increase lead time and cost.
Quantity & customization — one-off prototypes cost more per unit than production runs.
Testing & documentation — factory acceptance testing (FAT), test certificates, and EMI/insulation reports add to price.
Indicative price bands (for planning only): small single-phase units (sub-kVA) can be a few hundred USD; moderate industrial units (5–50 kVA) typically range from low hundreds to a few thousand USD; large three-phase or certified medical units are several thousand USD. For an accurate transformador de aislamiento precio tailored to your specs, please request a quote — we provide detailed, itemized offers.
How to select the right isolation transformer (quick guide)
Confirm load type: linear vs non-linear (harmonics).
Determine kVA, voltage, phase and allowed short-circuit impedance.
Decide leakage current limits and required grounding scheme (floating vs grounded secondary).
Specify environmental and enclosure requirements (IP, vibration, mounting).
Ask for test reports / certificates if your industry requires them.
Consider lifecycle costs: efficiency, maintenance, and serviceability.
Why choose ZHENGXI
ZHENGXI supplies custom and standard isolation transformers designed for demanding industrial, audio, medical and laboratory applications. Our manufacturing process includes precision winding, vacuum impregnation, strict QC testing and optional FAT documentation. We offer flexible customization, worldwide logistics and technical support to help you pick the right model — from small service isolation units to large three-phase power conditioners.
Preguntas frecuentes
Q1 — What’s the difference between an isolation transformer and an autotransformer? A: An isolation transformer has separate primary and secondary windings and provides galvanic isolation between circuits — important for safety and noise reduction. An autotransformer shares a winding for input and output (no galvanic isolation) and is typically smaller and cheaper but does not provide the safety benefits of isolation.
Q2 — Can an isolation transformer remove harmonics and protect against surges? A: Isolation transformers can attenuate certain harmonic components (especially low-order/common-mode harmonics) and reduce common-mode noise; some core designs also limit surge energy. However, they are not a universal harmonic filter — for severe harmonic distortion or demanding surge protection, combine the transformer with active filters, surge protectors or dedicated EMI filters.
Q3 — How much does an isolation transformer cost? A:Isolation transformer price depends on kVA, phase, voltage, construction, shielding, enclosure, testing and certification. We provide competitive, detailed quotes — send your required kVA/voltage/installation details and we’ll return a tailored offer with lead time and optional test documentation.
Ready to specify a model or get an exact transformador de aislamiento precio? Contact our sales team with your application details (kVA, voltage, phase, environment and any required certifications) and we’ll prepare a no-obligation quote and datasheet.
La serie JMB es nuestro transformador de control monofásico robusto y portátil diseñado para iluminación y pequeños equipos industriales. Reduce las tensiones de red comunes a salidas aisladas de muy baja tensión de seguridad (SELV), ideales para obras húmedas, espacios reducidos y recintos metálicos en los que la seguridad es importante. Disponible desde 25 VA hasta 50 kVA, con múltiples tomas y funciones de protección opcionales.
El transformador de control trifásico en seco de la serie SBK (500VA-1kVA) ofrece una conversión de tensión compacta y fiable para aplicaciones de control industrial, automatización y maquinaria. Disponible con tensiones primarias y secundarias configurables (estándar: 380 V / 400 V / 415 V) y apto para sistemas de 50 Hz o 60 Hz, este transformador está diseñado para redes de baja tensión (<1 kV). Su construcción seca y refrigerada por aire elimina el aceite, reduce el riesgo de incendio y disminuye el mantenimiento rutinario, lo que lo convierte en una opción segura y rentable para centros de control de motores, sistemas CNC, armarios PLC y paneles de distribución.
Garantice una calidad de alimentación impecable y la máxima seguridad para cargas sensibles con el Transformador toroidal de aislamiento GBK2. Diseñado para aplicaciones que exigen bajo nivel de ruido, bajas fugas y salida estable (220 V → 220 V), la serie GBK2 aísla su equipo de las perturbaciones de la red eléctrica, suprime los transitorios y reduce las interferencias de modo común. Su núcleo toroidal compacto ofrece mayor eficiencia y menor zumbido audible que los transformadores laminados convencionales, ideal para dispositivos médicos, audio profesional, instrumentos de laboratorio y controles industriales.
En Serie JBK es un compacto de tipo seco transformador de control Concebido para el control y aislamiento de máquinas en paneles industriales. El uso típico es 220 V → 110 V circuitos de control para contactores, relés, PLC y sensores. Fabricado para ofrecer bajo nivel de ruido, alta fiabilidad y fácil montaje en armario, el JBK protege los circuitos de control de las perturbaciones de la red eléctrica a la vez que simplifica el cableado y el mantenimiento.