Air circuit breakers are one of the important protective devices in electrical systems, which can help avoid overloads, short circuits, and other abnormal conditions in both high- and low-voltage power distribution systems. Among technical parameters, IR is an important term related to the performance and application of circuit breakers. This article will give you a detailed introduction to what IR in air circuit breakers is and their function.

Definition of IR

Generally speaking, IR usually means “In Rated Current Range”, that is, rated current range. In fact, it means the range of value with which the current can make the circuit breaker work stably for a long time. In fact, the IR parameter of a circuit breaker sets its protection value to allow operation under normal conditions of load of the circuit and to be able to trip in time at an increase of the value of the current above that set for protection.

IR Function

IR setting decides the overload protection feature of the circuit breaker. The main functions of IR include:

Protection of equipment safety: preventing the destruction of the equipment in the circuit due to overloading.

Improvement of system reliability: ensuring a stable power supply when the load fluctuates to avoid false tripping.

Being flexible to different load environments: it can adapt to the current requirements of various devices by adjusting IR.

How to set the IR value?

Setting the IR value must consider the characteristic and safety needs of the circuit; therefore, general principles are as follows:

Based on the type of load: the IR is valued according to calculations concerning maximum operational current values of the system, adding to them a small additional value.

Reference to rated current of device: The IR value should not be more than the rated current of the device; otherwise, it will burn the device.

Consider environmental factors: a high temperature will increase the current, so the IR value should be reduced according to this.

The relationship between IR and other parameters

Besides IR, air circuit breakers have some related parameters, including:

ISD: Short-time delay current setting, applied for protection against short-circuit.

Im: This is an instantaneous current setting to serve the purpose of rapidly cutting off severe short-circuit conditions.

PREGUNTAS FRECUENTES

Q1: What would be the effect of setting IR too high or too low?

If IR is set too high, under overload conditions, the circuit breaker may fail to trip in time, hence causing damage to the equipment.

If IR is set too low, it may trip the circuit breaker frequently and impact the normal operation of the system.

Q2: How to set the IR parameter?
Most of the modern air circuit breakers have an adjustable knob or a digital interface that can easily adjust the value of IR. Its adjustment should be done with the manufacturer’s instructions.

Resumen

IR is regarded as one of the important parameters in air circuit breakers and thus IR is very important for safety and stability during the operation of a circuit. A proper value of IR will effectively protect the electrical equipment and enhance system reliability. In case one is not sure about IR setting, it is advisable to consult a professional electric engineer.

Productos relacionados

FKN12A-12 Interruptor-seccionador de alto voltaje en vacío para interiores LBS con eslabón fusible

Tipo:FKN12A-12 Este interruptor-seccionador de vacío de alta tensión puede instalarse junto con el interruptor de puesta a tierra y tiene la función de cerrar la corriente de cortocircuito. El interruptor permite dos modos diferentes - modo manual y eléctrico. Su uso en sistemas de potencia le permite cumplir con tres tipos de controles (remoto, telemetría y teleseñalización).

Alta Calidad VS1 12kv Alta Tensión Interruptor Automático De Aire Sólido Para Interruptores De Interior VCB

Poder de corte:31,5kA, 80kA Tensión nominal:12kV Corriente nominal:1250A Nombre del producto:Interruptor automático de vacío de interior Norma:GB/T 1984-2014 Frecuencia:50HZ OEM:Ofertado

VF(R)-12kv Interruptor automático en vacío de media tensión CA de alto voltaje incorporado

El disyuntor de media tensión de alta tensión VF(R)-12kV AC es una nueva generación de equipos de alta tensión desarrollada para satisfacer la demanda del mercado. Adopta conceptos de diseño modernos y está diseñado específicamente para aparamenta interior blindada aislada en aire para garantizar un funcionamiento seguro y estable dentro del rango de tensión nominal. El VF(R)-12 es un aparato combinado de interruptor y fusible de CA de carga de alta tensión altamente integrado, adecuado para una gran variedad de sistemas de red eléctrica, y su diseño se centra en el avance y la fiabilidad. En los sistemas de alimentación modernos, goza de gran popularidad entre los usuarios por su excelente rendimiento y su amplia gama de aplicaciones.

ZN85-40.5 Interruptor automático de vacío VCB de alta tensión para interior para aparamenta KYN61

El interruptor automático de vacío de alta tensión para interiores ZN85-40.5 es un tipo de dispositivo eléctrico de alta tensión para sistemas de alimentación de CA 50 Hz, 35 kV, especialmente adecuado para carros de transformadores de tensión en celdas de 1200 mm de ancho. En la estructura del propio disyuntor no se ha previsto ningún mecanismo de accionamiento. Sirve para la operación PT fijo-móvil en alta tensión y está diseñado en la búsqueda de la medición segura y eficiente de la tensión en el sistema de alta tensión y la protección del sistema.

Will be used in accordance with our Privacy Policy