{"id":23547,"date":"2026-08-14T09:42:24","date_gmt":"2026-08-14T09:42:24","guid":{"rendered":"https:\/\/www.tronkiele.com\/?p=23547"},"modified":"2026-09-30T08:57:54","modified_gmt":"2026-09-30T08:57:54","slug":"what-is-electrical-switchgear-types-components-selection-guide","status":"publish","type":"post","link":"https:\/\/www.tronkiele.com\/fa\/what-is-electrical-switchgear-types-components-selection-guide\/","title":{"rendered":"\u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0642\u0637\u0639 \u0648 \u0648\u0635\u0644 \u0628\u0631\u0642 \u0686\u06cc\u0633\u062a\u061f \u0627\u0646\u0648\u0627\u0639\u060c \u0627\u062c\u0632\u0627 \u0648 \u0631\u0627\u0647\u0646\u0645\u0627\u06cc \u0627\u0646\u062a\u062e\u0627\u0628"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><a href=\"\/fa\/product-category\/electrical-switchgear\/\">\u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0633\u0648\u0626\u06cc\u0686\u06cc\u0646\u06af \u0627\u0644\u06a9\u062a\u0631\u06cc\u06a9\u06cc<\/a> is an essential part of a power distribution system. It controls the flow of electricity, protects equipment when faults occur, and allows circuits to be safely isolated for maintenance.<\/p><p class=\"wp-block-paragraph\">You will find switchgear in factories, commercial buildings, data centers, substations, renewable energy projects, mining facilities, and other installations where electrical power needs to be distributed safely and reliably.<\/p><p class=\"wp-block-paragraph\">But switchgear is more than an electrical cabinet with a circuit breaker inside. Its configuration depends on the system voltage, load current, short-circuit level, protection requirements, installation environment, and applicable electrical standards.<\/p><p class=\"wp-block-paragraph\">This guide explains how electrical switchgear works, its main components and types, and what engineers and buyers should consider when selecting switchgear for a project.<\/p><h2 class=\"wp-block-heading\">\u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0633\u0648\u0626\u06cc\u0686\u06cc\u0646\u06af \u0627\u0644\u06a9\u062a\u0631\u06cc\u06a9\u06cc \u0686\u06cc\u0633\u062a\u061f<\/h2><p class=\"wp-block-paragraph\"><strong>Electrical switchgear is an assembly of switching, protection, control, measurement, and isolation devices used to manage electrical power within a distribution system.<\/strong><\/p><p class=\"wp-block-paragraph\">Depending on the design, a switchgear assembly may include:<\/p><ul class=\"wp-block-list\"><li>\u0634\u0633\u062a\u06cc\u200c\u0647\u0627\u06cc \u0642\u0637\u0639 \u062c\u0631\u06cc\u0627\u0646<\/li>\n\n<li>Disconnectors or isolators<\/li>\n\n<li>Earthing switches<\/li>\n\n<li>Protection relays<\/li>\n\n<li>\u0634\u06cc\u0646\u0647\u200c\u0647\u0627<\/li>\n\n<li>Current transformers (CTs)<\/li>\n\n<li><a href=\"\/fa\/product-category\/power-transformer\/\">Voltage transformers<\/a> (VTs\/PTs)<\/li>\n\n<li>Fuses<\/li>\n\n<li>Surge arresters<\/li>\n\n<li>Meters<\/li>\n\n<li>Control and communication devices<\/li><\/ul><p class=\"wp-block-paragraph\">In practical terms, switchgear performs three main functions:<\/p><p class=\"wp-block-paragraph\"><strong>Control:<\/strong> Connect or disconnect electrical circuits and equipment.<\/p><p class=\"wp-block-paragraph\"><strong>\u062d\u0641\u0627\u0638\u062a:<\/strong> Interrupt abnormal current caused by short circuits, overloads, or other electrical faults.<\/p><p class=\"wp-block-paragraph\"><strong>Isolation:<\/strong> Separate equipment from energized sections so inspection and maintenance can be carried out safely.<\/p><p class=\"wp-block-paragraph\">A circuit breaker is therefore only one component of a <a href=\"\/fa\/product-category\/electrical-switchgear\/\">switchgear system<\/a>\u2014not the complete switchgear itself.<\/p><h2 class=\"wp-block-heading\">How Does Electrical Switchgear Work?<\/h2><p class=\"wp-block-paragraph\">During normal operation, electrical power typically follows a path such as:<\/p><p class=\"wp-block-paragraph\"><strong>Power Source \u2192 Incoming Breaker \u2192 Busbar \u2192 Feeder Breaker \u2192 Load<\/strong><\/p><p class=\"wp-block-paragraph\">The incoming breaker and feeder breakers remain closed while power is supplied to transformers, motors, distribution panels, VFDs, or other downstream loads.<\/p><p class=\"wp-block-paragraph\">Protection devices continuously monitor electrical conditions.<\/p><p class=\"wp-block-paragraph\">If a fault occurs on an outgoing feeder, for example, current transformers provide measurement signals to the protection relay. When the relay detects a condition outside its configured protection limits, it sends a trip command to the appropriate circuit breaker.<\/p><p class=\"wp-block-paragraph\">The breaker opens and interrupts the fault current.<\/p><p class=\"wp-block-paragraph\">In a properly designed protection system, the objective is to disconnect the affected section rather than unnecessarily shut down the entire installation. This protection coordination is particularly important in industrial plants, data centers, hospitals, utilities, and other facilities where continuity of power matters.<\/p><h2 class=\"wp-block-heading\">Main Components of Electrical Switchgear<\/h2><p class=\"wp-block-paragraph\">The exact equipment depends on the voltage level, application, and project specification, but the following components are commonly found in switchgear.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Component<\/th><th>\u0639\u0645\u0644\u06a9\u0631\u062f \u0627\u0635\u0644\u06cc<\/th><\/tr><\/thead><tbody><tr><td><strong>Circuit Breaker<\/strong><\/td><td>Makes and breaks circuits and interrupts fault current<\/td><\/tr><tr><td><strong>Disconnector \/ Isolator<\/strong><\/td><td>Provides visible or defined electrical isolation<\/td><\/tr><tr><td><strong>Earthing Switch<\/strong><\/td><td>Grounds isolated circuits for maintenance<\/td><\/tr><tr><td><strong>Busbar<\/strong><\/td><td>Carries and distributes power between circuits<\/td><\/tr><tr><td><strong>Protection Relay<\/strong><\/td><td>Detects abnormal conditions and initiates protective action<\/td><\/tr><tr><td><strong>Current Transformer (CT)<\/strong><\/td><td>Provides current signals for protection and metering<\/td><\/tr><tr><td><strong>Voltage Transformer (VT\/PT)<\/strong><\/td><td>Provides voltage signals for measurement and protection<\/td><\/tr><tr><td><strong>Fuse<\/strong><\/td><td>Provides overcurrent protection in suitable applications<\/td><\/tr><tr><td><strong>Surge Arrester<\/strong><\/td><td>Helps protect equipment against transient overvoltage<\/td><\/tr><tr><td><strong>Metering Device<\/strong><\/td><td>Measures voltage, current, power, energy, and other parameters<\/td><\/tr><tr><td><strong>Control System<\/strong><\/td><td>Provides local or remote switching, monitoring, and communication<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">For modern industrial projects, protection relays, digital meters, communication interfaces, remote monitoring, and SCADA integration may also form part of the switchgear configuration.<\/p><hr class=\"wp-block-separator has-alpha-channel-opacity\"\/><h1 class=\"wp-block-heading\">Types of Electrical Switchgear<\/h1><p class=\"wp-block-paragraph\">Switchgear can be classified by voltage level, insulation method, installation environment, and construction.<\/p><p class=\"wp-block-paragraph\">For most industrial and commercial projects, the first distinction is the system voltage.<\/p><h2 class=\"wp-block-heading\">Low-Voltage Switchgear<\/h2><p class=\"wp-block-paragraph\">Low-voltage switchgear is commonly used for power distribution in factories, commercial buildings, infrastructure, data centers, and other low-voltage installations.<\/p><p class=\"wp-block-paragraph\">Under the IEC framework, the IEC 61439 series covers low-voltage switchgear and controlgear assemblies. IEC 61439-1 establishes general requirements for assemblies with rated voltages not exceeding 1,000 V AC or 1,500 V DC.<\/p><p class=\"wp-block-paragraph\">\u06a9\u0627\u0631\u0628\u0631\u062f\u0647\u0627\u06cc \u0645\u0639\u0645\u0648\u0644 \u0639\u0628\u0627\u0631\u062a\u0646\u062f \u0627\u0632:<\/p><ul class=\"wp-block-list\"><li>Main low-voltage distribution<\/li>\n\n<li>\u062e\u0637\u0648\u0637 \u0635\u0646\u0639\u062a\u06cc production<\/li>\n\n<li>Motor distribution and control<\/li>\n\n<li>\u0633\u0627\u062e\u062a\u0645\u0627\u0646\u200c\u0647\u0627\u06cc \u062a\u062c\u0627\u0631\u06cc<\/li>\n\n<li>\u0645\u0631\u0627\u06a9\u0632 \u062f\u0627\u062f\u0647<\/li>\n\n<li>Generator and backup power systems<\/li><\/ul><h2 class=\"wp-block-heading\">Medium-Voltage Switchgear<\/h2><p class=\"wp-block-paragraph\">Medium-voltage switchgear is widely used between the incoming power source, transformers, and downstream distribution equipment.<\/p><p class=\"wp-block-paragraph\">Common system voltage classes encountered in industrial and utility projects include:<\/p><p class=\"wp-block-paragraph\"><strong>3.3 kV, 6 kV, 10 kV, 11 kV, 12 kV, 15 kV, 24 kV, 33 kV, 35 kV, and 40.5 kV.<\/strong><\/p><p class=\"wp-block-paragraph\">Actual equipment ratings depend on the electrical system and applicable standard.<\/p><p class=\"wp-block-paragraph\">For AC metal-enclosed switchgear, IEC 62271-200 covers equipment rated above 1 kV and up to and including 52 kV.<\/p><p class=\"wp-block-paragraph\">Medium-voltage switchgear is commonly used in:<\/p><ul class=\"wp-block-list\"><li>Distribution substations<\/li>\n\n<li>\u06a9\u0627\u0631\u062e\u0627\u0646\u0647\u200c\u0647\u0627\u06cc \u062a\u0648\u0644\u06cc\u062f\u06cc<\/li>\n\n<li>Mining facilities<\/li>\n\n<li>\u067e\u0631\u0648\u0698\u0647\u200c\u0647\u0627\u06cc \u0627\u0646\u0631\u0698\u06cc \u062a\u062c\u062f\u06cc\u062f\u067e\u0630\u06cc\u0631<\/li>\n\n<li>Oil and gas facilities<\/li>\n\n<li>\u0645\u0631\u0627\u06a9\u0632 \u062f\u0627\u062f\u0647<\/li>\n\n<li>Water treatment facilities<\/li>\n\n<li>Rail and transportation infrastructure<\/li><\/ul><p class=\"wp-block-paragraph\">Vacuum circuit breakers are widely used in modern medium-voltage switchgear because of their switching performance and relatively low maintenance requirements.<\/p><h2 class=\"wp-block-heading\">\u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0633\u0648\u0626\u06cc\u0686\u06cc\u0646\u06af \u0648\u0644\u062a\u0627\u0698 \u0628\u0627\u0644\u0627<\/h2><p class=\"wp-block-paragraph\">High-voltage switchgear is primarily associated with transmission networks, generating stations, and large utility substations.<\/p><p class=\"wp-block-paragraph\">At higher voltage levels, insulation coordination, electrical clearances, fault interruption capability, switching performance, and personnel safety become increasingly specialized.<\/p><p class=\"wp-block-paragraph\">For industrial buyers whose projects are primarily within low- and medium-voltage distribution, LV and MV switchgear specifications are normally more relevant than transmission-level HV equipment.<\/p><h1 class=\"wp-block-heading\">Air-Insulated vs Gas-Insulated Switchgear<\/h1><p class=\"wp-block-paragraph\">Another important distinction is how energized components are insulated.<\/p><h2 class=\"wp-block-heading\">\u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0633\u0648\u0626\u06cc\u0686\u06cc\u0646\u06af \u0639\u0627\u06cc\u0642\u200c\u0634\u062f\u0647 \u0628\u0627 \u0647\u0648\u0627 (AIS)<\/h2><p class=\"wp-block-paragraph\">Air-insulated switchgear uses air as an important part of its insulation system.<\/p><p class=\"wp-block-paragraph\">AIS is widely used because it offers:<\/p><ul class=\"wp-block-list\"><li>Established technology<\/li>\n\n<li>Relatively straightforward construction<\/li>\n\n<li>Flexible configurations<\/li>\n\n<li>Easier access for inspection<\/li>\n\n<li>Good expandability<\/li>\n\n<li>Competitive initial cost in many projects<\/li><\/ul><p class=\"wp-block-paragraph\">Its main limitation is space. Required electrical clearances generally make AIS larger than equivalent compact gas-insulated designs.<\/p><h2 class=\"wp-block-heading\">\u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0633\u0648\u0626\u06cc\u0686\u06cc\u0646\u06af \u0639\u0627\u06cc\u0642\u200c\u0634\u062f\u0647 \u0628\u0627 \u06af\u0627\u0632 (GIS)<\/h2><p class=\"wp-block-paragraph\">Gas-insulated switchgear places major energized components inside sealed compartments using an insulating gas or gas mixture.<\/p><p class=\"wp-block-paragraph\">Its compact design makes GIS useful where installation space is limited, including:<\/p><ul class=\"wp-block-list\"><li>\u0632\u06cc\u0631\u200c\u0633\u062a\u06af\u0627\u0647\u200c\u0647\u0627\u06cc \u0634\u0647\u0631\u06cc<\/li>\n\n<li>Underground installations<\/li>\n\n<li>Metro systems<\/li>\n\n<li>Mining projects<\/li>\n\n<li>Space-constrained industrial facilities<\/li><\/ul><p class=\"wp-block-paragraph\">When comparing AIS and GIS, footprint should not be the only consideration. Buyers should also evaluate maintenance requirements, environmental conditions, project standards, lifecycle cost, and the insulation technology being used.<\/p><h1 class=\"wp-block-heading\">Switchgear vs Switchboard vs Circuit Breaker<\/h1><p class=\"wp-block-paragraph\">These terms are related but should not automatically be treated as interchangeable.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u062a\u062c\u0647\u06cc\u0632\u0627\u062a<\/th><th>Main Role<\/th><\/tr><\/thead><tbody><tr><td><strong>\u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0642\u0637\u0639 \u0648 \u0648\u0635\u0644<\/strong><\/td><td>Switching, protection, fault interruption, isolation, control, and power distribution<\/td><\/tr><tr><td><strong>Switchboard<\/strong><\/td><td>Primarily distributes electrical power among multiple downstream circuits<\/td><\/tr><tr><td><strong>Circuit Breaker<\/strong><\/td><td>Individual protective switching device used to make, carry, and interrupt current<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">The exact terminology can vary between IEC, ANSI\/IEEE, UL, and regional practices.<\/p><p class=\"wp-block-paragraph\">For procurement purposes, it is better to compare the actual electrical ratings, construction, protection functions, and applicable standards rather than relying only on the product name.<\/p><h1 class=\"wp-block-heading\">Where Is Electrical Switchgear Used?<\/h1><p class=\"wp-block-paragraph\">Switchgear is used wherever electrical power needs to be distributed while maintaining protection, control, and isolation.<\/p><h2 class=\"wp-block-heading\">Industrial Plants<\/h2><p class=\"wp-block-paragraph\">Factories use switchgear to distribute incoming power to transformers, production lines, motors, VFD systems, compressors, pumps, HVAC equipment, and other machinery.<\/p><p class=\"wp-block-paragraph\">For larger facilities, medium-voltage switchgear may distribute power to several transformers or major production areas before voltage is stepped down for individual loads.<\/p><h2 class=\"wp-block-heading\">Utility and Distribution Substations<\/h2><p class=\"wp-block-paragraph\">Switchgear protects transformers, controls incoming and outgoing feeders, isolates equipment, and divides the distribution network into manageable sections.<\/p><h2 class=\"wp-block-heading\">Data Centers and Commercial Facilities<\/h2><p class=\"wp-block-paragraph\">Data centers require carefully coordinated electrical distribution because continuity of power is critical.<\/p><p class=\"wp-block-paragraph\">Switchgear may form part of a system containing:<\/p><p class=\"wp-block-paragraph\"><strong>Utility Supply \u2192 MV Switchgear \u2192 Transformer \u2192 LV Switchgear \u2192 UPS \u2192 IT Loads<\/strong><\/p><p class=\"wp-block-paragraph\">The exact architecture depends on the required redundancy and reliability level.<\/p><h2 class=\"wp-block-heading\">Renewable Energy Projects<\/h2><p class=\"wp-block-paragraph\">Solar and wind installations require switching and protection between generation equipment, transformers, collection networks, substations, and grid connections.<\/p><h2 class=\"wp-block-heading\">Mining and Infrastructure<\/h2><p class=\"wp-block-paragraph\">Mining sites, airports, railways, water treatment plants, ports, and other large infrastructure projects often use medium-voltage distribution to transfer substantial amounts of electrical power around the site.<\/p><hr class=\"wp-block-separator has-alpha-channel-opacity\"\/><h1 class=\"wp-block-heading\">Key Switchgear Ratings You Need to Understand<\/h1><p class=\"wp-block-paragraph\">One of the most common purchasing mistakes is selecting switchgear based only on system voltage.<\/p><p class=\"wp-block-paragraph\">\u06cc\u06a9 <strong>11 kV switchgear cabinet<\/strong>, for example, cannot be properly specified without additional electrical information.<\/p><h2 class=\"wp-block-heading\">\u0648\u0644\u062a\u0627\u0698 \u0646\u0627\u0645\u06cc<\/h2><p class=\"wp-block-paragraph\">The switchgear voltage rating must correspond to the electrical system and its insulation requirements.<\/p><p class=\"wp-block-paragraph\">For an 11 kV system, the equipment&#8217;s rated voltage class will depend on the applicable standard and project specification.<\/p><h2 class=\"wp-block-heading\">\u062c\u0631\u06cc\u0627\u0646 \u0646\u0627\u0645\u06cc<\/h2><p class=\"wp-block-paragraph\">Rated current indicates the continuous current that the main circuit can carry under specified operating conditions.<\/p><p class=\"wp-block-paragraph\">Typical values may include:<\/p><p class=\"wp-block-paragraph\"><strong>630 A, 1,250 A, 1,600 A, 2,000 A, 2,500 A, and 3,150 A.<\/strong><\/p><p class=\"wp-block-paragraph\">The required value depends on the incoming supply, transformer capacity, feeder loads, busbar arrangement, and system design.<\/p><h2 class=\"wp-block-heading\">\u062c\u0631\u06cc\u0627\u0646 \u0645\u0642\u0627\u0648\u0645\u062a \u06a9\u0648\u062a\u0627\u0647\u200c\u0645\u062f\u062a<\/h2><p class=\"wp-block-paragraph\">This rating indicates the current that the switchgear can withstand for a specified short duration.<\/p><p class=\"wp-block-paragraph\">A specification may therefore include values such as:<\/p><p class=\"wp-block-paragraph\"><strong>25 kA \/ 3 s<\/strong><\/p><p class=\"wp-block-paragraph\">The required rating must be coordinated with the calculated prospective short-circuit current at the installation point.<\/p><h2 class=\"wp-block-heading\">Circuit Breaker Rating<\/h2><p class=\"wp-block-paragraph\">For medium-voltage applications, buyers should specify or confirm parameters such as:<\/p><ul class=\"wp-block-list\"><li>\u0648\u0644\u062a\u0627\u0698 \u0646\u0627\u0645\u06cc<\/li>\n\n<li>\u062c\u0631\u06cc\u0627\u0646 \u0646\u0627\u0645\u06cc<\/li>\n\n<li>Short-circuit breaking current<\/li>\n\n<li>Operating mechanism<\/li>\n\n<li>Control voltage<\/li>\n\n<li>Mechanical and electrical requirements<\/li><\/ul><h2 class=\"wp-block-heading\">Internal Arc Classification<\/h2><p class=\"wp-block-paragraph\">For certain medium-voltage metal-enclosed switchgear applications, internal arc classification is an important personnel-safety consideration.<\/p><p class=\"wp-block-paragraph\">IEC 62271-200 includes requirements related to internal arc testing and classification.<\/p><p class=\"wp-block-paragraph\">The required classification should be defined during project design rather than assumed from the appearance of the enclosure.<\/p><hr class=\"wp-block-separator has-alpha-channel-opacity\"\/><h1 class=\"wp-block-heading\">How to Select the Right Electrical Switchgear<\/h1><p class=\"wp-block-paragraph\">Switchgear should be selected as part of the complete electrical system.<\/p><p class=\"wp-block-paragraph\">Before requesting a quotation, determine the following information.<\/p><h3 class=\"wp-block-heading\">1. System Voltage and Frequency<\/h3><p class=\"wp-block-paragraph\">\u0645\u062b\u0627\u0644\u200c\u0647\u0627:<\/p><ul class=\"wp-block-list\"><li>10 kV \/ 50 Hz<\/li>\n\n<li>11 kV \/ 50 Hz<\/li>\n\n<li>13.8 kV \/ 60 Hz<\/li>\n\n<li>33 kV \/ 50 Hz<\/li><\/ul><h3 class=\"wp-block-heading\">2. Required Continuous Current<\/h3><p class=\"wp-block-paragraph\">Determine the required current for the incoming circuit, busbar, bus coupler, and outgoing feeders.<\/p><h3 class=\"wp-block-heading\">3. Prospective Short-Circuit Current<\/h3><p class=\"wp-block-paragraph\">The switchgear withstand and circuit breaker interruption ratings must be suitable for the calculated fault level.<\/p><h3 class=\"wp-block-heading\">4. Number of Incoming and Outgoing Feeders<\/h3><p class=\"wp-block-paragraph\">A manufacturer needs to understand the required panel lineup.<\/p><p class=\"wp-block-paragraph\">\u0628\u0631\u0627\u06cc \u0645\u062b\u0627\u0644:<\/p><p class=\"wp-block-paragraph\"><strong>1 Incoming + 1 PT + 1 Bus Coupler + 6 Outgoing Feeders<\/strong><\/p><p class=\"wp-block-paragraph\">provides much more useful information than simply requesting \u201c11 kV switchgear.\u201d<\/p><h3 class=\"wp-block-heading\">5. Circuit Breaker Requirements<\/h3><p class=\"wp-block-paragraph\">Specify the required breaker type and electrical ratings.<\/p><p class=\"wp-block-paragraph\">Vacuum circuit breakers are commonly used in medium-voltage applications.<\/p><h3 class=\"wp-block-heading\">6. Indoor or Outdoor Installation<\/h3><p class=\"wp-block-paragraph\">Environmental conditions can directly affect switchgear design.<\/p><p class=\"wp-block-paragraph\">Important information may include:<\/p><ul class=\"wp-block-list\"><li>\u062f\u0645\u0627\u06cc \u0645\u062d\u06cc\u0637<\/li>\n\n<li>\u0631\u0637\u0648\u0628\u062a<\/li>\n\n<li>\u0627\u0631\u062a\u0641\u0627\u0639<\/li>\n\n<li>Dust<\/li>\n\n<li>Corrosive atmosphere<\/li>\n\n<li>Indoor\/outdoor installation<\/li>\n\n<li>Required IP rating<\/li><\/ul><h3 class=\"wp-block-heading\">7. Protection Requirements<\/h3><p class=\"wp-block-paragraph\">The protection scheme may require functions for:<\/p><ul class=\"wp-block-list\"><li>Overcurrent<\/li>\n\n<li>Earth fault<\/li>\n\n<li>Under\/overvoltage<\/li>\n\n<li>Transformer protection<\/li>\n\n<li>Motor protection<\/li>\n\n<li>Differential protection<\/li><\/ul><p class=\"wp-block-paragraph\">Actual functions depend on the electrical system and project specification.<\/p><h3 class=\"wp-block-heading\">8. Metering and Communication<\/h3><p class=\"wp-block-paragraph\">If the switchgear will be integrated into a plant automation or SCADA system, specify communication and monitoring requirements during the design stage.<\/p><h3 class=\"wp-block-heading\">9. Applicable Standard<\/h3><p class=\"wp-block-paragraph\">Project specifications may reference standards such as:<\/p><ul class=\"wp-block-list\"><li>IEC 61439<\/li>\n\n<li>IEC 62271<\/li>\n\n<li>IEEE C37<\/li>\n\n<li>GB standards<\/li>\n\n<li>Utility-specific standards<\/li><\/ul><h3 class=\"wp-block-heading\">10. Single-Line Diagram<\/h3><p class=\"wp-block-paragraph\">For customized switchgear, the <strong>single-line diagram (SLD)<\/strong> is one of the most useful documents you can provide to the manufacturer.<\/p><p class=\"wp-block-paragraph\">It shows the relationship between:<\/p><p class=\"wp-block-paragraph\"><strong>Incoming Supply \u2192 Bus Sections \u2192 Transformers \u2192 Feeders \u2192 Major Loads<\/strong><\/p><p class=\"wp-block-paragraph\">and helps the manufacturer determine the appropriate panel configuration.<\/p><hr class=\"wp-block-separator has-alpha-channel-opacity\"\/><h1 class=\"wp-block-heading\">Switchgear RFQ Checklist<\/h1><p class=\"wp-block-paragraph\">If you are preparing an inquiry for medium-voltage switchgear, the following information can make technical evaluation and quotation much faster.<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Required Information<\/th><th>\u0645\u062b\u0627\u0644<\/th><\/tr><\/thead><tbody><tr><td>System Voltage<\/td><td>\u06f1\u06f1 \u06a9\u06cc\u0644\u0648\u0648\u0644\u062a<\/td><\/tr><tr><td>\u0641\u0631\u06a9\u0627\u0646\u0633<\/td><td>50 Hz<\/td><\/tr><tr><td>Rated Busbar Current<\/td><td>1250 A<\/td><\/tr><tr><td>\u062c\u0631\u06cc\u0627\u0646 \u0645\u0642\u0627\u0648\u0645\u062a \u06a9\u0648\u062a\u0627\u0647\u200c\u0645\u062f\u062a<\/td><td>25 kA \/ 3 s<\/td><\/tr><tr><td>Incoming Feeders<\/td><td>1<\/td><\/tr><tr><td>Outgoing Feeders<\/td><td>6<\/td><\/tr><tr><td>Circuit Breaker<\/td><td>\u0634\u0633\u062a\u06cc \u0642\u0637\u0639\u200c\u06a9\u0646\u0646\u062f\u0647\u0654 \u062e\u0644\u0623<\/td><\/tr><tr><td>CT Ratio<\/td><td>According to load\/protection requirement<\/td><\/tr><tr><td>PT\/VT Requirement<\/td><td>Project-specific<\/td><\/tr><tr><td>\u0646\u0635\u0628<\/td><td>\u0641\u0636\u0627\u06cc \u062f\u0627\u062e\u0644\u06cc<\/td><\/tr><tr><td>Protection Relay<\/td><td>Specify required functions\/brand if applicable<\/td><\/tr><tr><td>\u0627\u0631\u062a\u0628\u0627\u0637\u0627\u062a<\/td><td>Specify protocol if required<\/td><\/tr><tr><td>Applicable Standard<\/td><td>IEC 62271-200<\/td><\/tr><tr><td>Single-Line Diagram<\/td><td>\u062a\u0648\u0635\u06cc\u0647 \u0634\u062f\u0647<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"wp-block-paragraph\">For an actual project, additional information may be required depending on the switchgear design and local electrical requirements.<\/p><h1 class=\"wp-block-heading\">Important Switchgear Standards<\/h1><p class=\"wp-block-paragraph\">The applicable standard depends on the country, voltage class, equipment type, utility requirements, and project specification.<\/p><p class=\"wp-block-paragraph\">Frequently referenced standards include:<\/p><p class=\"wp-block-paragraph\">IEC 61439 Series Covers low-voltage switchgear and controlgear assemblies.<\/p><p class=\"wp-block-paragraph\">IEC 62271-1 Provides common specifications for AC switchgear and controlgear above 1,000 V.<\/p><p class=\"wp-block-paragraph\">IEC 62271-200 Applies to AC metal-enclosed switchgear and controlgear rated above 1 kV and up to and including 52 kV.<\/p><p class=\"wp-block-paragraph\">When purchasing switchgear internationally, confirm the required standard before finalizing the equipment configuration.<\/p><h1 class=\"wp-block-heading\">A Practical Example: Specifying an 11 kV Switchgear Project<\/h1><p class=\"wp-block-paragraph\">Consider a factory that needs medium-voltage switchgear for an 11 kV incoming supply.<\/p><p class=\"wp-block-paragraph\">Simply sending:<\/p><blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cWe need 11 kV switchgear.\u201d<\/p><\/blockquote><p class=\"wp-block-paragraph\">is not enough for an accurate configuration.<\/p><p class=\"wp-block-paragraph\">A more useful inquiry would look like this:<\/p><p class=\"wp-block-paragraph\"><strong>System:<\/strong> 11 kV, 50 Hz<br><strong>Busbar:<\/strong> 1250 A<br><strong>Short-circuit rating:<\/strong> 25 kA \/ 3 s<br><strong>Configuration:<\/strong> 1 incoming + 1 PT + 1 bus coupler + 6 outgoing panels<br><strong>Breaker:<\/strong> Vacuum circuit breaker<br><strong>Installation:<\/strong> \u0641\u0636\u0627\u06cc \u062f\u0627\u062e\u0644\u06cc<br><strong>Standard:<\/strong> IEC 62271-200<br><strong>\u062d\u0641\u0627\u0638\u062a:<\/strong> Digital protection relay<br><strong>Control power:<\/strong> Project specified<br><strong>Drawing:<\/strong> Single-line diagram available<\/p><p class=\"wp-block-paragraph\">With this information, the manufacturer can evaluate the panel configuration, breaker ratings, busbar requirements, CT\/PT arrangement, protection scheme, and enclosure design much more accurately.<\/p><p class=\"wp-block-paragraph\">This is why switchgear selection should begin with the electrical system rather than the cabinet dimensions or appearance.<\/p><h1 class=\"wp-block-heading\">\u067e\u0631\u0633\u0634\u200c\u0647\u0627\u06cc \u0645\u062a\u062f\u0627\u0648\u0644<\/h1><h2 class=\"wp-block-heading\">What is switchgear in simple terms?<\/h2><p class=\"wp-block-paragraph\">Switchgear is a group of electrical devices used to control, protect, and isolate circuits in a power distribution system. It typically includes circuit breakers, busbars, protection relays, disconnectors, CTs, VTs, and control equipment.<\/p><h2 class=\"wp-block-heading\">What is the difference between switchgear and a circuit breaker?<\/h2><p class=\"wp-block-paragraph\">A circuit breaker is an individual switching and protection device. Switchgear is the complete assembly that may contain circuit breakers together with busbars, relays, CTs, VTs, disconnectors, meters, control devices, and enclosures.<\/p><h2 class=\"wp-block-heading\">What is the difference between LV and MV switchgear?<\/h2><p class=\"wp-block-paragraph\">Low-voltage switchgear is used in low-voltage distribution systems, while medium-voltage switchgear is used at higher distribution voltages between power sources, transformers, and major loads. The applicable voltage ranges and equipment requirements depend on the relevant standards.<\/p><h2 class=\"wp-block-heading\">What is the difference between AIS and GIS?<\/h2><p class=\"wp-block-paragraph\">AIS uses air as an important part of its insulation system and generally requires more installation space. GIS uses sealed gas-insulated compartments, allowing a more compact design. Selection depends on space, environment, maintenance strategy, project standards, and lifecycle requirements.<\/p><h2 class=\"wp-block-heading\">What information should I provide when ordering MV switchgear?<\/h2><p class=\"wp-block-paragraph\">At minimum, provide:<\/p><ul class=\"wp-block-list\"><li>System voltage and frequency<\/li>\n\n<li>\u062c\u0631\u06cc\u0627\u0646 \u0646\u0627\u0645\u06cc<\/li>\n\n<li>Short-circuit level<\/li>\n\n<li>Incoming and outgoing feeder arrangement<\/li>\n\n<li>Circuit breaker requirements<\/li>\n\n<li>CT\/PT requirements<\/li>\n\n<li>\u0639\u0645\u0644\u06a9\u0631\u062f\u0647\u0627\u06cc \u062d\u0641\u0627\u0638\u062a\u06cc<\/li>\n\n<li>\u0645\u062d\u06cc\u0637 \u0646\u0635\u0628<\/li>\n\n<li>Applicable standard<\/li><\/ul><p class=\"wp-block-paragraph\">For customized projects, also provide the <strong>single-line diagram (SLD), transformer data, load information, and technical specification<\/strong> whenever available.<\/p><hr class=\"wp-block-separator has-alpha-channel-opacity\"\/><h1 class=\"wp-block-heading\">\u0646\u062a\u06cc\u062c\u0647\u200c\u06af\u06cc\u0631\u06cc<\/h1><p class=\"wp-block-paragraph\">Selecting electrical switchgear starts with the electrical system\u2014not simply the cabinet.<\/p><p class=\"wp-block-paragraph\">System voltage, rated current, short-circuit level, feeder arrangement, breaker ratings, protection requirements, installation environment, and applicable standards should all be established before the final switchgear configuration is determined.<\/p><p class=\"wp-block-paragraph\">For customized medium-voltage switchgear projects, preparing a clear single-line diagram and basic electrical specifications before requesting a quotation allows the manufacturer to evaluate the busbar, breaker, protection, CT\/PT, and panel configuration more accurately.<\/p><p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Electrical switchgear is an essential part of a power distribution system. It controls the flow of electricity, protects equipment when<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[95],"tags":[],"class_list":["post-23547","post","type-post","status-publish","format-standard","hentry","category-switchgear-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>What Is Electrical Switchgear? Types, Components &amp; Selection Guide - PINE<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tronkiele.com\/fa\/what-is-electrical-switchgear-types-components-selection-guide\/\" \/>\n<meta property=\"og:locale\" content=\"fa_IR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What Is Electrical Switchgear? Types, Components &amp; Selection Guide - PINE\" \/>\n<meta property=\"og:description\" content=\"Electrical switchgear is an essential part of a power distribution system. It controls the flow of electricity, protects equipment when\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tronkiele.com\/fa\/what-is-electrical-switchgear-types-components-selection-guide\/\" \/>\n<meta property=\"og:site_name\" content=\"PINE\" \/>\n<meta property=\"article:published_time\" content=\"2026-08-14T09:42:24+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-30T08:57:54+00:00\" \/>\n<meta name=\"author\" content=\"TRONKI\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0646\u0648\u0634\u062a\u0647\u200c\u0634\u062f\u0647 \u0628\u062f\u0633\u062a\" \/>\n\t<meta name=\"twitter:data1\" content=\"TRONKI\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0632\u0645\u0627\u0646 \u062a\u0642\u0631\u06cc\u0628\u06cc \u0628\u0631\u0627\u06cc \u062e\u0648\u0627\u0646\u062f\u0646\" \/>\n\t<meta name=\"twitter:data2\" content=\"11 \u062f\u0642\u06cc\u0642\u0647\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":[\"Article\",\"BlogPosting\"],\"@id\":\"https:\/\/www.tronkiele.com\/what-is-electrical-switchgear-types-components-selection-guide\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.tronkiele.com\/what-is-electrical-switchgear-types-components-selection-guide\/\"},\"author\":{\"name\":\"TRONKI\",\"@id\":\"https:\/\/www.tronkiele.com\/#\/schema\/person\/4cb742e1a580d7a81c864fb6632382e1\"},\"headline\":\"What Is Electrical Switchgear? Types, Components &#038; Selection Guide\",\"datePublished\":\"2026-08-14T09:42:24+00:00\",\"dateModified\":\"2026-09-30T08:57:54+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.tronkiele.com\/what-is-electrical-switchgear-types-components-selection-guide\/\"},\"wordCount\":2345,\"publisher\":{\"@id\":\"https:\/\/www.tronkiele.com\/#organization\"},\"articleSection\":[\"Switchgear Blog\"],\"inLanguage\":\"fa-IR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.tronkiele.com\/what-is-electrical-switchgear-types-components-selection-guide\/\",\"url\":\"https:\/\/www.tronkiele.com\/what-is-electrical-switchgear-types-components-selection-guide\/\",\"name\":\"What Is Electrical Switchgear? Types, Components & Selection Guide - PINE\",\"isPartOf\":{\"@id\":\"https:\/\/www.tronkiele.com\/#website\"},\"datePublished\":\"2026-08-14T09:42:24+00:00\",\"dateModified\":\"2026-09-30T08:57:54+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.tronkiele.com\/what-is-electrical-switchgear-types-components-selection-guide\/#breadcrumb\"},\"inLanguage\":\"fa-IR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.tronkiele.com\/what-is-electrical-switchgear-types-components-selection-guide\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.tronkiele.com\/what-is-electrical-switchgear-types-components-selection-guide\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.tronkiele.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What Is Electrical Switchgear? Types, Components &#038; Selection Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.tronkiele.com\/#website\",\"url\":\"https:\/\/www.tronkiele.com\/\",\"name\":\"PINE\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.tronkiele.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.tronkiele.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fa-IR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.tronkiele.com\/#organization\",\"name\":\"PINE\",\"url\":\"https:\/\/www.tronkiele.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fa-IR\",\"@id\":\"https:\/\/www.tronkiele.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.tronkiele.com\/wp-content\/uploads\/2024\/11\/cropped-tronki.webp\",\"contentUrl\":\"https:\/\/www.tronkiele.com\/wp-content\/uploads\/2024\/11\/cropped-tronki.webp\",\"width\":512,\"height\":512,\"caption\":\"PINE\"},\"image\":{\"@id\":\"https:\/\/www.tronkiele.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.tronkiele.com\/#\/schema\/person\/4cb742e1a580d7a81c864fb6632382e1\",\"name\":\"TRONKI\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fa-IR\",\"@id\":\"https:\/\/www.tronkiele.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/07dc6b945b6df01205b1ae74df3428f981607547b24d37324ab40c256f270a21?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/07dc6b945b6df01205b1ae74df3428f981607547b24d37324ab40c256f270a21?s=96&d=mm&r=g\",\"caption\":\"TRONKI\"},\"sameAs\":[\"http:\/\/www.tronkiele.com\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What Is Electrical Switchgear? Types, Components & Selection Guide - PINE","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tronkiele.com\/fa\/what-is-electrical-switchgear-types-components-selection-guide\/","og_locale":"fa_IR","og_type":"article","og_title":"What Is Electrical Switchgear? Types, Components & Selection Guide - PINE","og_description":"Electrical switchgear is an essential part of a power distribution system. It controls the flow of electricity, protects equipment when","og_url":"https:\/\/www.tronkiele.com\/fa\/what-is-electrical-switchgear-types-components-selection-guide\/","og_site_name":"PINE","article_published_time":"2026-08-14T09:42:24+00:00","article_modified_time":"2026-09-30T08:57:54+00:00","author":"TRONKI","twitter_card":"summary_large_image","twitter_misc":{"\u0646\u0648\u0634\u062a\u0647\u200c\u0634\u062f\u0647 \u0628\u062f\u0633\u062a":"TRONKI","\u0632\u0645\u0627\u0646 \u062a\u0642\u0631\u06cc\u0628\u06cc \u0628\u0631\u0627\u06cc \u062e\u0648\u0627\u0646\u062f\u0646":"11 \u062f\u0642\u06cc\u0642\u0647"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["Article","BlogPosting"],"@id":"https:\/\/www.tronkiele.com\/what-is-electrical-switchgear-types-components-selection-guide\/#article","isPartOf":{"@id":"https:\/\/www.tronkiele.com\/what-is-electrical-switchgear-types-components-selection-guide\/"},"author":{"name":"TRONKI","@id":"https:\/\/www.tronkiele.com\/#\/schema\/person\/4cb742e1a580d7a81c864fb6632382e1"},"headline":"What Is Electrical Switchgear? Types, Components &#038; Selection Guide","datePublished":"2026-08-14T09:42:24+00:00","dateModified":"2026-09-30T08:57:54+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tronkiele.com\/what-is-electrical-switchgear-types-components-selection-guide\/"},"wordCount":2345,"publisher":{"@id":"https:\/\/www.tronkiele.com\/#organization"},"articleSection":["Switchgear Blog"],"inLanguage":"fa-IR"},{"@type":"WebPage","@id":"https:\/\/www.tronkiele.com\/what-is-electrical-switchgear-types-components-selection-guide\/","url":"https:\/\/www.tronkiele.com\/what-is-electrical-switchgear-types-components-selection-guide\/","name":"What Is Electrical Switchgear? Types, Components & Selection Guide - PINE","isPartOf":{"@id":"https:\/\/www.tronkiele.com\/#website"},"datePublished":"2026-08-14T09:42:24+00:00","dateModified":"2026-09-30T08:57:54+00:00","breadcrumb":{"@id":"https:\/\/www.tronkiele.com\/what-is-electrical-switchgear-types-components-selection-guide\/#breadcrumb"},"inLanguage":"fa-IR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tronkiele.com\/what-is-electrical-switchgear-types-components-selection-guide\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.tronkiele.com\/what-is-electrical-switchgear-types-components-selection-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tronkiele.com\/"},{"@type":"ListItem","position":2,"name":"What Is Electrical Switchgear? Types, Components &#038; Selection Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.tronkiele.com\/#website","url":"https:\/\/www.tronkiele.com\/","name":"\u06a9\u0627\u062c","description":"","publisher":{"@id":"https:\/\/www.tronkiele.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tronkiele.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fa-IR"},{"@type":"Organization","@id":"https:\/\/www.tronkiele.com\/#organization","name":"\u06a9\u0627\u062c","url":"https:\/\/www.tronkiele.com\/","logo":{"@type":"ImageObject","inLanguage":"fa-IR","@id":"https:\/\/www.tronkiele.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.tronkiele.com\/wp-content\/uploads\/2024\/11\/cropped-tronki.webp","contentUrl":"https:\/\/www.tronkiele.com\/wp-content\/uploads\/2024\/11\/cropped-tronki.webp","width":512,"height":512,"caption":"PINE"},"image":{"@id":"https:\/\/www.tronkiele.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.tronkiele.com\/#\/schema\/person\/4cb742e1a580d7a81c864fb6632382e1","name":"\u062a\u0631\u0648\u0646\u06a9\u06cc","image":{"@type":"ImageObject","inLanguage":"fa-IR","@id":"https:\/\/www.tronkiele.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/07dc6b945b6df01205b1ae74df3428f981607547b24d37324ab40c256f270a21?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/07dc6b945b6df01205b1ae74df3428f981607547b24d37324ab40c256f270a21?s=96&d=mm&r=g","caption":"TRONKI"},"sameAs":["http:\/\/www.tronkiele.com"]}]}},"_links":{"self":[{"href":"https:\/\/www.tronkiele.com\/fa\/wp-json\/wp\/v2\/posts\/23547","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tronkiele.com\/fa\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tronkiele.com\/fa\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tronkiele.com\/fa\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tronkiele.com\/fa\/wp-json\/wp\/v2\/comments?post=23547"}],"version-history":[{"count":4,"href":"https:\/\/www.tronkiele.com\/fa\/wp-json\/wp\/v2\/posts\/23547\/revisions"}],"predecessor-version":[{"id":23579,"href":"https:\/\/www.tronkiele.com\/fa\/wp-json\/wp\/v2\/posts\/23547\/revisions\/23579"}],"wp:attachment":[{"href":"https:\/\/www.tronkiele.com\/fa\/wp-json\/wp\/v2\/media?parent=23547"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tronkiele.com\/fa\/wp-json\/wp\/v2\/categories?post=23547"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tronkiele.com\/fa\/wp-json\/wp\/v2\/tags?post=23547"}],"curies":[{"name":"\u0648\u06cc\u200c\u067e\u06cc","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}