Air circuit breakers are one of the important protective devices in electrical systems, which can help avoid overloads, short circuits, and other abnormal conditions in both high- and low-voltage power distribution systems. Among technical parameters, IR is an important term related to the performance and application of circuit breakers. This article will give you a detailed introduction to what IR in air circuit breakers is and their function.

Definition of IR

Generally speaking, IR usually means “In Rated Current Range”, that is, rated current range. In fact, it means the range of value with which the current can make the circuit breaker work stably for a long time. In fact, the IR parameter of a circuit breaker sets its protection value to allow operation under normal conditions of load of the circuit and to be able to trip in time at an increase of the value of the current above that set for protection.

IR Function

IR setting decides the overload protection feature of the circuit breaker. The main functions of IR include:

Protection of equipment safety: preventing the destruction of the equipment in the circuit due to overloading.

Improvement of system reliability: ensuring a stable power supply when the load fluctuates to avoid false tripping.

Being flexible to different load environments: it can adapt to the current requirements of various devices by adjusting IR.

How to set the IR value?

Setting the IR value must consider the characteristic and safety needs of the circuit; therefore, general principles are as follows:

Based on the type of load: the IR is valued according to calculations concerning maximum operational current values of the system, adding to them a small additional value.

Reference to rated current of device: The IR value should not be more than the rated current of the device; otherwise, it will burn the device.

Consider environmental factors: a high temperature will increase the current, so the IR value should be reduced according to this.

The relationship between IR and other parameters

Besides IR, air circuit breakers have some related parameters, including:

ISD: Short-time delay current setting, applied for protection against short-circuit.

Im: This is an instantaneous current setting to serve the purpose of rapidly cutting off severe short-circuit conditions.

FAQ

Q1: What would be the effect of setting IR too high or too low?

If IR is set too high, under overload conditions, the circuit breaker may fail to trip in time, hence causing damage to the equipment.

If IR is set too low, it may trip the circuit breaker frequently and impact the normal operation of the system.

Q2: How to set the IR parameter?
Most of the modern air circuit breakers have an adjustable knob or a digital interface that can easily adjust the value of IR. Its adjustment should be done with the manufacturer’s instructions.

Sintesi

IR is regarded as one of the important parameters in air circuit breakers and thus IR is very important for safety and stability during the operation of a circuit. A proper value of IR will effectively protect the electrical equipment and enhance system reliability. In case one is not sure about IR setting, it is advisable to consult a professional electric engineer.

Prodotti correlati

FKN12A-12 Interruttore di carico sottovuoto per interni ad alta tensione LBS con collegamento al fusibile

Tipo: FKN12A-12 Questo interruttore sottovuoto ad alta tensione può essere installato insieme all'interruttore di messa a terra e ha la funzione di chiudere la corrente di cortocircuito. L'interruttore consente due diverse modalità: manuale ed elettrica. Il suo impiego nei sistemi di alimentazione consente di soddisfare tre tipi di controllo (remoto, telemetrico e di telesegnalazione).

Alta qualità VS1 12kv ad alta tensione Indoor solido aria interruttore automatico VCB per il dispositivo di commutazione

Capacità di rottura: 31,5kA, 80kA Tensione nominale: 12kV Corrente nominale: 1250A Nome del prodotto: Interruttore sottovuoto da interno Standard: GB/T 1984-2014 Frequenza: 50HZ OEM: Offerta

Interruttore automatico sottovuoto di media tensione AC VF(R)-12kv incorporato ad alta tensione

L'interruttore di media tensione VF(R)-12kV AC è una nuova generazione di apparecchiature ad alta tensione sviluppata per soddisfare la domanda del mercato. Adotta concetti di design moderni ed è progettato specificamente per i commutatori blindati interni isolati in aria, per garantire un funzionamento sicuro e stabile nell'intervallo di tensione nominale. VF(R)-12 è un apparecchio combinato di interruttore e fusibile per carichi ad alta tensione altamente integrato, adatto a una varietà di sistemi di rete elettrica e il cui design è incentrato su progresso e affidabilità. Nei moderni sistemi di alimentazione, è molto apprezzato dagli utenti per le sue eccellenti prestazioni e l'ampia gamma di scenari di applicazione.

Interruttore automatico sottovuoto VCB ad alta tensione per interni ZN85-40,5 per il quadro KYN61

L'interruttore automatico sottovuoto ad alta tensione per interni ZN85-40.5 è un tipo di dispositivo elettrico ad alta tensione per sistemi di alimentazione a 50 Hz in corrente alternata e 35 kV, particolarmente adatto al carrello del trasformatore di tensione in un quadro elettrico di 1200 mm di larghezza. Nella struttura dell'interruttore stesso non è previsto un meccanismo di funzionamento. L'interruttore serve per il funzionamento fisso-mobile in alta tensione ed è progettato per garantire una misurazione efficiente e sicura della tensione nel sistema ad alta tensione e la protezione del sistema.

Will be used in accordance with our Privacy Policy