Air circuit breakers are one of the important protective devices in electrical systems, which can help avoid overloads, short circuits, and other abnormal conditions in both high- and low-voltage power distribution systems. Among technical parameters, IR is an important term related to the performance and application of circuit breakers. This article will give you a detailed introduction to what IR in air circuit breakers is and their function.

Definition of IR

Generally speaking, IR usually means “In Rated Current Range”, that is, rated current range. In fact, it means the range of value with which the current can make the circuit breaker work stably for a long time. In fact, the IR parameter of a circuit breaker sets its protection value to allow operation under normal conditions of load of the circuit and to be able to trip in time at an increase of the value of the current above that set for protection.

IR Function

IR setting decides the overload protection feature of the circuit breaker. The main functions of IR include:

Protection of equipment safety: preventing the destruction of the equipment in the circuit due to overloading.

Improvement of system reliability: ensuring a stable power supply when the load fluctuates to avoid false tripping.

Being flexible to different load environments: it can adapt to the current requirements of various devices by adjusting IR.

How to set the IR value?

Setting the IR value must consider the characteristic and safety needs of the circuit; therefore, general principles are as follows:

Based on the type of load: the IR is valued according to calculations concerning maximum operational current values of the system, adding to them a small additional value.

Reference to rated current of device: The IR value should not be more than the rated current of the device; otherwise, it will burn the device.

Consider environmental factors: a high temperature will increase the current, so the IR value should be reduced according to this.

The relationship between IR and other parameters

Besides IR, air circuit breakers have some related parameters, including:

ISD: Short-time delay current setting, applied for protection against short-circuit.

Im: This is an instantaneous current setting to serve the purpose of rapidly cutting off severe short-circuit conditions.

ЧАСТО ЗАДАВАЕМЫЕ ВОПРОСЫ

Q1: What would be the effect of setting IR too high or too low?

If IR is set too high, under overload conditions, the circuit breaker may fail to trip in time, hence causing damage to the equipment.

If IR is set too low, it may trip the circuit breaker frequently and impact the normal operation of the system.

Q2: How to set the IR parameter?
Most of the modern air circuit breakers have an adjustable knob or a digital interface that can easily adjust the value of IR. Its adjustment should be done with the manufacturer’s instructions.

Резюме

IR is regarded as one of the important parameters in air circuit breakers and thus IR is very important for safety and stability during the operation of a circuit. A proper value of IR will effectively protect the electrical equipment and enhance system reliability. In case one is not sure about IR setting, it is advisable to consult a professional electric engineer.

Сопутствующие товары

FKN12A-12 Внутренний высоковольтный вакуумный выключатель нагрузки LBS с плавкой вставкой

Тип:FKN12A-12 Этот вакуумный выключатель нагрузки высокого напряжения может быть установлен вместе с заземляющим устройством, имеющим функцию замыкания тока короткого замыкания. Выключатель позволяет использовать два различных режима - ручной и электрический. Его использование в энергосистемах позволяет совместить его с тремя типами управления (дистанционным, телеметрическим и телесигнализацией).

Высокомарочный VS1 12kv высоковольтный крытый твердый воздушный автоматический выключатель VCB для распределительного устройства

Отключающая способность:31.5kA, 80kA Номинальное напряжение:12кВ Номинальный ток:1250A Название продукта:Внутренний вакуумный автоматический выключатель Стандарт:GB/T 1984-2014 Частота:50HZ OEM:предлагается

VF(R)-12kv встраиваемый высоковольтный вакуумный выключатель переменного тока среднего напряжения

Высоковольтный выключатель среднего напряжения переменного тока VF(R)-12kV - это новое поколение высоковольтного оборудования, разработанное с учетом требований рынка. Он использует современные концепции дизайна и разработан специально для закрытых распределительных устройств с воздушной изоляцией, чтобы обеспечить безопасную и стабильную работу в диапазоне номинального напряжения. VF(R)-12 - это высокоинтегрированный высоковольтный переключатель нагрузки переменного тока и комбинированный предохранитель, который подходит для различных систем электросетей, а в его конструкции особое внимание уделяется усовершенствованию и надежности. В современных энергосистемах он пользуется большим спросом у пользователей благодаря своим превосходным характеристикам и широкому спектру вариантов применения.

ZN85-40.5 Внутренний высоковольтный вакуумный выключатель VCB для распределительного устройства KYN61

Высоковольтный вакуумный выключатель ZN85-40.5 для установки в помещениях - это высоковольтное электрическое устройство, рассчитанное на работу в электросети переменного тока 50 Гц, 35 кВ и особенно подходящее для установки на тележку трансформатора напряжения в распределительном устройстве шириной 1200 мм. В конструкции самого выключателя не предусмотрен механизм управления. Он служит для неподвижной работы при высоком напряжении и предназначен для эффективного безопасного измерения напряжения в высоковольтной системе и защиты системы.

Will be used in accordance with our Privacy Policy